May 08
Document Date unknown · 5 page(s) in the original
This is the document's text, extracted automatically. Headings and paragraphs are inferred from the original's layout, so the arrangement may differ from the published version — the words do not. Where it matters legally, the original governs.
Queen Anne's County Department of Planning and Zoning BUILDING PERMIT No.: BR25-014064 110 Vincit St, Suite 104 Date of Applicatlon | 0112712026 Centreville, MD 21617 410-7s84088
BUILDING PERMIT
BUILDING LOCATION 104 CLARK CT PRoPERTY owNERS: CD REED & SONS ASSOCIATES
MILLINGTON REED, ROGER
PO BOX 188
Kennedyville, MD 21645 rAx AccouNr 1807015.t 51
SUBDIVISION CHESTER RIVER HEIGHTS HOME PHONE: (410) 490-0708
YES
CRITICAL AREA ACREAGE 0.62 APPLICANT:
TAX MAP OOO1 GRID OOOT PARCEL 0109
SECTION BLOCK
LOT 26
ZONED NC-1 FRONTAGE DEPTH STAKED: E YES E NO g WLL CALL
EXISTING USE RESIDENCE FEES
PARKS & REC $801.35 SINGLE LOT $55.00
PROPOSED USE SINGLE FAMILY OWELLING SPRINKLER $1s0.00 ELECT. ADMIN. $10.00
BOCA FEE $216.44 ELECT. PERMIT $115.00
REVISED PROPOSED USE
FIRE DIST 7 $831.60 ZONING $ss.00
SCHOOLS $7,212.24 3 PERCENT $132.68
coNsTRucTroN vALUE $150,000.00 AOMIN FEE TO
BALANCE OF
IMPACT FEE
MHB FEE $50 00
CONTRACTORS NAME LICENSE # PHONE# PERMIT#
MHBR ROGER L. REED MHBR.2464 (302) 545-9625
PO 8OX 188, KENNEOYVILLE, MD 21645
ELECTRICIAN GARRETT GERMAN & SONS INC E+571 (410],758-0225 ER25-01-0064
PLUMBER TIM THE PLUMBER PR-371 (4'10) 758-4399 P4417-25
SPRINKLER METROPOLITAN FIRE MSC+155 (301) 868-0005 BF-0418-25
HVAC PUCKETTS HEATING AND AIR HM-4S0 1443) 239-2129 H-0456-25
CONOITIONING
DEscRlPrloN oF woRK: CONSTRUCT 2 STORY SFD. FIRST FLOOR 26'X 36'OVERALL TO INCLUDE 10'X 16'
REAR PATIO. SECONO FLOOR 16' X 36' OVERALL,
BUILDING DESCRIPTION OIMENSIONS (IN SOUARE FEET) cONSTRUcTION TYPE: WOOD FRAME
UNFIN, BASEMENT: FIN BASEMENT: # BEDROOMS: 3 # BATHROOMS: 3
FIRST FLOORT 936 SECONO FLOOR. 576 ROAD TYPE: COUNTY SPRINKLER: YES
THIRD FLOOR: FOURTII FLOOR WATER TYPE PRIVATE SEWER TYPE PRIVATE
GARAGE:
CARPORT: HEATING SYSTEM: HEAT PUMP CENTRAL AIR: YES
DECK|
PORCH: FIREPLACE: NONE
OTHER: 160 REAR PATIO
TOTAL FLOOR AREA: '1,672
The undersigned hereby cedifies and agrees as follows: (1 ) That he/she is authorized to make this application; (2) that the information is correct;
(3) that he,lhe will comply with all regulaticns of Queen Anne's County vrhich are applicable lherelo; (,{) that he/she will perfom no \rork on the
above referenced prope(y not specilically descdbed in this application; (5) that he/she grants County Oflicials lhe righl to enter onto lhis property for lhe purpose of inspecting the \r/ork permitted and posting notices.
NOTE: Separato oloctrlcal and plumbing pq,mtas are roquiredl A pe]mit undor whlch no work has commoncad withln six months attor Esuanco 3hall sxpiae. A pomlt uodor whlch rrork commonces withln slx months ghall be consid€rod lf constuctlon ls continuous, Conditions:
THE SCHOOL, FIRE. AND PARK LAND IMPACT FEES OF $4.422.65 HAVE BEEN DEFERRED. NO TEMPORARY OR FINAL OCCUPANCY CERTIFICATE WLL BE ISSUEO UNTIL FEES HAVE BEEN PAIO, AN ELECTRIC VEHICLE CFIARGING STATION IS REOUIRED, OSHA ANO ,''+ MOSHA REGULATIONS REQUIRE THAT EACH JOBSITE HAVE TOILET FACILITIES PROVIDED. OWNER MUST PLANT (9) IALL CONTA,NER GRO!\N NATIVE TREES PRIOR TO CERTIFICATE OF OCCUPANCY. CALL 410-758-4088 FOR INSPECTION. 51 ,1, - MUST
FOLLOWAPPROVED SUBDIVISION STORMWATER MANAGEMENT PLAN LOCATION SURVEY REQUIRED AT TIME OF THE FOUNOATION INSPECTION. OUEEN ANNE'S COUNTY FIRE MARSHAL: THIS PERMIT lS APPROVED SUBJECT TO THE ENCLOSED STATED COMtiENTS. NO INSPECTION \ ,lLL BE COMPLETEO UNLESS APPROVED STAMPED PLANS ANO COMMENTS ARE ON SITE.
FOR INFORMATION OR TO ARRANGE AN INSPECTION CALL 410.758-4500 EXT. ,1,I.I4,
OFFICE USE ONLY
MIN!MUM YARD REQUIREMENTS APPROVALS:
tl],o ACCESSORY STRUCTURE PRINCIPLE STRUCTURE EurLDrNGlitD 0411712025 FLOODPLAIN ZON 5t2025 FRONT FT FRONT 35 FT zoNrNd Jf) 03t0{.12025 PLUMBTNG(lA 04t28/2025
SIDE SIDE
REAR FT REAR 20 FT SEDIMENT 02tu12025 PUB. SEWER
FT 50 FT
STREET STREET HISTORIC 03t1&2025
SIDE FT SIDE FT
MAX. HGHT FT MAX. HGHT 40 FT SHA :rl;HffiL 02t05t2025 MECHANICALG/l 04n8t2025 (/1 05t04t2025 ELECTRICAL 03to3t2025 ee.cxrlow 04tz&2025 (*
FOOD SERVICE N/A ENV, HEALTH SEPTIC O4/15/2025
ENV, HEALTH WELL
5- x5 l/r,*"fdtu"'++-' DATE APPROVEO: AOMiNISTRATOR APPROVAL Queen Anne's County BUILDING PERMIT No.; BR25-03-0232 Oepartment of Planning and Zoning 110 Vincit St, Suite 104 Date of Application i 031'1912025 Centreville, MD 21617 410-758-4088
BUILDING PERMIT
BUILDING LOCATION 513 PATHFINDER CIR PROPERTY OWNERS: TOR PERRYS LLC
GRASONVILLE SHECKELLS, FRED
PO BOX 257
FALLSTON, MO 21047
TAX ACCOUNT 1805127155
HOME PHONE:
SUBDIVISION PERRY'S RETREAT
APPLICANT: PERI\iIITS PLUS, INC
NO
CRITICAL AREA ACREAGE
0-182 TERRI MCNICHOLAS
O58H OO21
TAX MAP GRID PARCEL O2O1 Po Box 690
SECTION BLOCK LOT 55 MILLERSVILLE MD 21108
ZONED GPRN FRONTAGE DEPTH STAKED: g YES E NO ! WTLLCALL
EXISTING USE VACANT LOT FEES
ZONING $55.U0 SINGLE LOT $55.00
PROPOSED USE SINGLE FAMILY OWELLING ELECT. ADMIN. $10.00 SPRINKLER $150.00 ELECT. PERMIT $165.00 scHooLs $ 13,87't.16 REVISED PROPOSEO USE FIRE DIST 2 $1,s99.40 BOCA FEE $418.40
MHB FEE $50.00 PARKS & REC $1,541.24
coNsTRucTroN VALUE $140,000.00
CONTRACTORS NAME LICENSE # PHONE# PERMIT#
MHBR NVR rNC (RYAN HOMES & NV) MHBL#56 (703)761-2000
9720 PATUXENT WOODS DR, COLUMBIA, MD 21046
HEATTNG PN-160
PLU |\il BE R oHESPEAKE PLUMBTNG & (302) 732-6006 P-0445-?5 rNC HM-594 HVAC SoUTHERN MARYLAND HTG & ArR (30'1) 645-6928 H-0440-25
PROTECTTON MSC-#49
SPRINKLER BAYSIOE FIRE (410) 286-3314 BF -0448-25
ELECTRICIAN cEco ELECTRIC E-OO024O-2022 (410) 995-6270 ER25-03-0232 DEscRlPTloN oF WORK: CONSTRUCT 2 STORY SFD. FIRST FLOOR 48'X 58' OVERALL TO INCLUDE 20' X 21' (2) cAR GARAGE AND 1o',X 20' (1) CAR GARAGE, 6'X 4'& 12', X T',FRONT COVERED PORCH, AND '10'X 14'REAR COVEREO PORCH, SECOND FLOOR 38' X 42' OVERALL.
MODEL: HUDSON, ELEVATION C
BUILOING DESCRIPTION DIMENSIONS (IN SAUARE FEET) CONSTRUCTION TYPE; WOOD FRAIVIE
UNFIN. BASEMENT: FIN BASEMENT: # BEDROOMS:4 # BATHROOMS:3
FIRST FLOOR: 1,398 SECOND FLOOR 1510 ROAD TYPE: COUNTY SPRINKLER: YES
THIRD FLOOR: FOURTH FLOOR: WATER TYPE PUBLIC SEWER TYPE PUBLIC
620
GARAGE: CARPORT: HEATING SYSTEM: HEAT PUMP CENTRAL AIRI YES
DECK]
PORCH:248 FIREPLAcE: NONE
OTHER:
TOTAL FLOOR AREA: 3,776
The undersigned hereby ce(ifies and agrees as follo^/sr (1 ) Tllat he/she is aulhorazed to make this application; (2) that the rnformation is correct;
(3) lhat he/she will comply wilh all regulations of Queen Anne's Counly which are applicable lhereto; (4) that he/she will pedorm no work on the
above referenced property not specilically described in th;s application; {5) lhal he/she grants Counly Offcials the righi 10 enter onto this properly for the purpose of inspecling lhe work permitted and posling notices.
NOTE: Separate olectrical and plumbing permits arg required! A permil under which no work has commencgd within six months after issuanc6 shall expire. A pgrmit undgl which wo.k commences within six months shall be considered if construction is continuous.
Conditions:
QUEEN ANNE S COUNTY FIRE MARSHAL: THIS PERMIT lS APPROVED SUBJECT TO THE ENCLOSED STATED COMI\,,lENTS. NO INSPECTION WLL BE COIIIPLETED UNLESS APPROVED STAMPED PLANS AND COMMENTS ARE ON SITE FOR INFORMATION OR TO ARRANGE AN INSPECTION CALL 4,10-758.4500 EXT, 1144, LOCATION SURVEY REOUIRED AT TI[,1E OF TBE FOUNDATION INSPECTION. S\AM ' MUSI FOLLOW APPROVED SUBOIVISION STORIVWATER MANAGEMENT PLAN AN ELECTRIC VEHICLE CHARGING
STATION IS REQUIRED, OSHA AND MOSHA REGULATIONS REQUIRE THAT EACH JOBSITE HAVE TOILET FACILITIES PROVIDED,
OFFICE USE ONLY
MINIMUM YARD REQUIREMENTS APPROVALS:
ACCESSORY STRUCTURE PRINCIPLE STRUCTURE BUILDINGTID 04102t2025 rroooerarq zourf5ao:rzozs FRONT FRONT prLltuerruo(2"\ FT 15 FT o41c8t2025 o4to3lzozs S R I E D A E R FT S R I E D A E R 5 FT ::Xil:JXL o3to2t2023 eue. sewenPl o+roaaozs
FT 20 FT
SIDE STREET FT SIDE STREET FT HISTORIC ixlnriffi 04t0212025 MAX. HGHT FT MAX. HGHT 40 FT SHA ,ceUA Mt0Lt202s MECHAN 04t03t2025 05ta5t2025 ELECTRICAL 03t24t2025 BAcKFLov., L,(4 0410312025 FOOD SERVICE N/A ENV HEALTH SEPTIC o+iozrzozslEN
ENV. HEALTH WELL
5 ,.e5
OATE APPROVEOI ADMINISTRATOR APPROVAL:
Queen Anne's County Department of Planning and Zoning BUILDING PERMIT No.: BR25{3-0259
I
1'10 Vincit St, Suite 104 Date of Application | 0312712025 Centreville, MD 216'll 410-758.4088
BUILDING PERMIT
BUILDING LOCATION 613 WARBLER WAY PROPERTY OWNERS I K HOVNANIAN'S FOUR SEASONS
CHESTER AT KENT ISLAND II LLC
101 LOG CANOE CIR C-2
STEVENSVILLE, MD 21666
TAX ACCOUNT 1804126682
HOME PHONE; (240) 375-473s
SUAOIVISION FOUR SEASONS AT KENT ISLAND
YES APPLICANT: K HOVNANIAN
CRITICAL AREA ACREAGE 0,14
OO49 OO2O LOLITA JUSTICE-WATKINS
T s A E X c M T AP t oN G B R L ID O CK PARCEL OOOT 101 Log Canoe Cir SUITE C2
LOT 642 STEVENSVILLE MD 21666
SMPD
ZONEO FRONTAGE43 DEP'IH 122 STAKEO: E YES D NO
M WILL CALL
EXISTING USE VACANT LOT FEES
BOCA FEE $295.80 SINGLE LOT $55.00
PROPOSED USE 4SEASONS .SFD ELECT. AOMIN. $10.00 4SEASNDRRA $10,546.00
ELECT. PERMIT $135.00 ZONING $55.00
REVISED PROPOSED USE
SPRINKLER s150.00 MHB FEE $50.00
COPIES AND $25.00
CONSTRUCTION VALUE S,I 95,OOO,OO Mtsc CONTRACTORS NAIIiE LICENSE # PHONE# PERMIT#
MHBR K HOVNANIAN'S FOUR SEASONS AT KENT MHBL#3,149 (301) 683-6275
ISLAND III LLC
101 LOG CANOE CIR C-2, STEVENSVILLE, MD 2'1666
HVAC MCCREA EOUIPMENT COMPANY, INC HR616 (301) 423-6623 H-O473-25
SPRINKLER METROPOLITAN FIRE MSC+155 (301) 868-0005 BF-0480-25
ELECTRICIAN TRI.STATE COMMUNICATIONS SERVICES E+8,I7 (301) 261-4943 ER25-03-0259
PLUMBER BLUESTREAM SERVICES INC PN#220 (410) 363-0072 P-0479-25
oEscRlPTloN oF woRK: GoNSTRUCT 1 sroRY sFD. FlRsr FLooR 35'x 80'4' oVERALL To |NCLUDE 20'6" x 19'8'GARAGE, 1O'2'X 18'8" SCREENED PATIO, AND 5'X 4'4",6'X 16'6" "1'SHAPED FRONT PORCH-
JENKINS FD PHASE IV
55+ AGE RESTRICTED COMMUNITY
BUILDING EESCRIPTION OltilENStONS (IN SOUARE FEET) CONSTRUCTION TYPE: WOOD FRAME
BASEMENT:
UNFIN. FIN BASEMENTI # BEDROOMS: 2 # BATHROOMS: 2
1,993
FIRST FLOOR: SECOND FLOOR ROAD TYPE: PRIVATE SPRINKLER: YES
FLOOR:
THIRD FOURTH FLOOR WATER TYPE PUBLIC SEWER TYPE PUBLIC
398
GARAGE: CARPORT: HEATING SYSTEM: GAS CENTRAL AIR: YES
DECK.
PORCH:120 FIREPLACE: GAS
OTHER: 190 - SCREENED PATIO
TOTAL FLOOR AREA; 2,701
The undersigned hereby cerlitles and agrees as follows: (1 ) That he/she is authorized to make this application; (2) that the informat,on is correct;
(3) thal he/she will comply with all regulations of Queen Anne's County which are applicable theretoi (4) lhal he/she witl perform no work on the
above rcIerenced property not specilically described in this applicationi (5) that he/she grants County Offcials the right to enter onto this property for the purpose of inspecting the work pe.mitted and posting notices NOTE: Soparato olectrlcal and plumbing pormits aro,equiredl A pgrmlt undgrryhlch no wo.k has commenced wlthln six months aller Bsuanco ahall etpire. A pqimlt underwhich wo,k commoncG withln slr months shall bs considorod ll construction is
continuoua.
Conditions:
LOCATION SURVEY REQUIRED AT TIME OF THE FOUNDATION INSPECTION, OSHA AND MOSHA REGULATIONS REOUIRE THAT EACH JOBSITE HAVE TOILET FACILITIES PROVIDED, SWM - MUST FOLLOW APPROVED SUEDIVISION STORMWATER MANAGEMENT PLAN QUEEN ANNE'S COUNTY FIRE MARSHAL: THIS PERMIT IS APPROVED SUBJECT TO THE ENCLOSED STATED COMMENTS. NO INSPECTION WlLL BE COI\,IPLETED UNLESS APPROVEO STAMPED PLANS AND COI\,IMENTS ARE ON SITE. FOR tNFORI\,AT|ON OR TO
ARRANGE AN INSPECTION CALL 410-758.4500 EXT. .] 144,
OFFICE USE ONLY
MIiiIMUM YARD REQIJIREMENTS APPROVALS:
ACCESSORY STRUC URE PRINCIPLE STRUCTURE BU'LDINGttD 04109t2025 Fr..ooDPLArN zONAu4/09/202s
FRONT FRONT MO
SIDE FT 20 FT zoNrNG 0d,130t2025 PLUMBTNGCTI C!,t}st20'.5 REAR FT SIDE 5FT sEDTMENT^VL 01125t2024 PUB SEWERE(. O4iO9/2025 STREET FT REAR 10 FT HISTORIC N/A s w. MGr lAl- o4tost2ozs SIDE FT SIDE STREET FT f\ft, MAX. HGHT FT MAX. HGHT 40 FT SHA N/A ENTRANCE orosrzozs MECHANTcA(121 Mt0st2025 rrne raansxn-r-,,1$ ovosrzozs ELECTRICAL unal2025 BACKFLOW Ln 0/,iO9t2O25 FOOO SERVICE N/A exrr. nerutx {E{; ollosrzozs
EI.IV. HEALTH WELL
5*e
DATE APPROVED: ADITTINISTRATOR APPROVAL:
Queen Anne's County Department of Planning and Zonlng BUILDING PERMIT No.: BR25{4-0287 110 Vincit St, Suite 104 Date of Application:. 04107 12025 Centreville, MD 216,t 7 410-758.4088
BUILOING PERMIT
BUILDING LOCATION 327 KINGFISHER LN PRoPERTY owNERs: K HOVNANIAN'S FOUR SEASONS
CHESTER AT KENT ISLAND II LLC
101 LOG CANOE CtR C-2
STEVENSVILLE, MD 21666
TAX ACCOUNT 1804126624
PHoNE:
HoME (240) 375-4735
SUBDIVISION FOUR SEASONS AT KENT ISLAND
YES APPLICANT: K HOVNANTAN
CRITICAL AREA ACREAGE 0,149
OO49 OO2O LOLITA JUSTICE-WATKINS
T s A E X c M T AP r oN B GR L ID O CK PARCEL OOOT 101 Log Canoe Cir SUITE C2
LOT 584 STEVENSVILLE MD 21666
ZONED SMPD FRONTAGE 58.5 OEPTH '12.2 STAXEO: Ll YES tr NO Et WTLLCALL
EXISTING USE VACANT LOT FE ES
BOCA FEE $469.76 SPRINKLER $150.00
PROPOSEO USE 4SEASONS -SFD ELECT. AOMIN. s10.00 ELECT. PERMIT $135.00
SINGLE LOT $55.00 45EASNDRRA $10,546.00
REVISED PROPOSED USE
MHB FEE $50.00 ZONING $s5.00
COPIES AND $30.00
CONSTRUCTION VALUE $1 95.OOO,OO Mtsc
CONTRACTORS NAME LICENSE # PHONE# PERMIT#
MHBR K HOVNANIAN'S FOUR SEASONS AT KENT MHBL#3149 (301) 683-6275
ISLAND III LLC
101 LOG CANOE CIR C.2. STEVENSVILLE. MD 21666
INC
HVAC MCCREA EQUIPMENT COMPANY, HR-616 (301) 423-6623 H{558-25
SPRINKLER METROPOLITAN FIRE MSC+155 (301) 868-0005 BF-0568-25
ELECTRICIAN TRI.STATE COMMUNICATIONS SERVICES E+817 (30'1) 261-4943 ER25-04{287
PLUMBER BLUESTREAM SERVICES INC PN#220 (410) 363-0072 P4567-25
DEscRlPrloN oF woRK: CONSTRUCT 2 STORY SFD. FIRST FLOOR 39'4" X 80'4' OVERALL TO INCLUDE 10'X 6' 6'X 21',"1" SHAPEO FRONT pORCH, 10'5" X 14'10", 20' X 19,1 1" (3) CAR GARAGE. ANO 19'8' X 14'2'
SCREENEO PATIO, SECOND FLOOR 36'6" X 39'4" OVERALL WITH LOFT,
TUSCALOOSA ED, PHASE IV
55+ AGE RESTRICTED COMMUNIw BUILDING DESCRIPTION DIMENSIONS (IN SQi'ARE FEET) CONSTRUCTIoN TYPE: WOOD FRAME
BASEMENT:
UNFIN. FlN EASEMENT: # BEDROOMS: 5 # BATHROOMS: 5 2,008 FIRST FLOOR: SECOND FLOoR: 1214 ROAD TYPE: PRIVATE SPRINKLER: YES
FLOOR:
THIRD FOURTH FLOOR: WATER TYPE PUBLIC SEWER TYPE PUBLIC
570
GARAGE: CARPORT: HEATING SYSTEM: GAS CENTRAL AIR: YES
DECX|
PORCH:189 FIREPLACE: GAS
oTHER: 280 - SCREENED PAI lO
TOTAL FLOOR AREA: 4,261
The uhdersigned hereby @dilies and ag.ees as follo,s: (1 ) That he/she is authorized lo make thas application; (2) that llle information as coffecl:
(3) that he/she will comply with ail regutalions of Oueen A ne,s County wtlich are applicabte theretoi (4) that he/she wilt perlorm no work on lhe
above referenced property not specillcally described an this applicalion; (5) that he/she grants County Oficials the right to enter onto thas property for the purpose of inspecting the work permifled and postiog nolices.
I{OTE: Separato elsctrical and pllrmblng pemits a.9 roqulred! A peimit undsr whlch no work has commencEd wlthln sir months aftet bsuanco ahall oxplro. A p€rmlt underwhich work commgncgs wllhln Blx rhonths shall bo considered it constructlon is contlnuous.
Conditions:
OUEEN ANNE'S COUNTY FIRE iTARSHAL: THIS PERMIT lS APPROVED SUBJECT TO THE ENCLOSED STATED COMMENTS. NO INSPECTION WLL 8E COMPLETED UNI.ESS APPROVED STAI\,IPED PLANS AND COMMENTS ARE ON SITE, FOR INFORMATION OR TO ARRANGE AN INSPECTION CALL 410"75&4500 EXT, 1144, S\AA,,I - MUST FOLLOW APPROVED SUBDIVISION STORMWATER MANAGEMENT PLAN LOCATION SURVEY REQUIR€D AT TIME OF THE FOUNDATION INSPECTION, OSHA AND IVIOSHA REGULATIONS
REOUIRE THAT EACH JOBSITE HAVE TOILET FACILIIIES PROVIDED,
OFFICE USE ONLY
MINIMUM YARD REQUIREMENTS APPROVALS:
ACCESSORY STRUCTURE PRINCIPLE STRUCTURE BUILDINGTTD Mt17 t2025 FLOODPLA[,r ZONs\94/1 7/2025 FRONT FT FRONT 20 FT zoNtNG \,,tO u!24t2025 PLTjMBTNGL{a\ o5to1t2o25
SIDE
REAR FT S R IO E E AR 5FT sEDTMENTl\2- 01t25t2024 PUB SEWER la(- c5to7t2o25 STREET FT 1 OFT HISTORIC :#Ji:.H ##r:
SIDE FT SIDE STREET FT
HGHT HGHT
MAX. FT MAX. 40 FT i?l,o","o.Ch os.t01t2025 FtREMARSHATf,B orm/2025 ELECTRICAL ut21t2025 BACKFLOW(.]h O5tO1t2O25 Jhl FOOO SERVICE ENV. irEALrH M/2112025
ENV. HEALTH WELL
W^
DArEAPPRoVED. _1}_:5:45 ADMINISTRATOR APPROVAL:
Queen Anne's County Department ot Plannlng and Zoning BUILDING PERMIT No.: BR25-03-0262 110 Vinclt St, Suire 't04 Date of Application: 0312712025 Centreville, MO 216'17 4't0-758{0E8
BUILDING PERMIT
EUILDING LOCATION 609 WARBLER WAY PROPERW owNERs: K HOVNANIAN'S FOUR SEASONS
CHESTER AT KENT ISLAND II LLC
't0t Loc cANoE ctR c_2
STEVENSVILLE, MO 21666
TAX ACCOUNT 1404126683
PHoNE:
HoME (240) 3754735
SUBDIVISION FOUR SEASONS AT KENT ISLAND
CRITICAL AREA YES ACREAGE 0,14 APPLICANT: K HOVNANIAN
T S A E X C MA T P I O O N O 49 G B R L ID O O C O K 2 O PARCEL OOOT L 1 O 01 L I L T o A g J C U a S n T o I e C E C - i W r S A U T I K T I E N S C2
LOT 643 STEVENSVILLE MD 21666
ZONED SMPD FRONTAGE 43 DEPTH122 STAKED: E YES E NO
MWTLLCALL
EXISTING USE RESIDENTIAL FE ES
ELECT. PERMIT $135.00 SPRINKLER $150.00
PROPOSED USE 45EASONS .SFO ZONING $55.00 SINGLE LOT $55.00
4SEASNDRRA $10,546.00 MHB FEE $50.00
REVISED PROPOSED USE
COPIES AND $2s.00 ELECT. ADMIN. $10.00 Mtsc
CONSTRUCTION VALUE $ 195,OOO,OO BOCA FEE $295 30
CONTRACTORS NAME LICENSE # PHONE# PERMIT#
[TH BR K HOVNANIAN'S FOUR SEASONS AT KENT IVHBL#3149 (301) 683-6275
ISTAND III LLC
101 LOG CANOE CIR C-2, STEVENSVILLE, MD 21666
INC
HVAC MCCREA EOUIPMENT COIUPANY. HR616 (301) 4236623 H-047 4-25
SPRINKLER METROPOLITAN FIRE MSC+'155 (301) 868-0005 BF-0481-25
ELECTRICIAN TRI.STATE COMMUNICATIONS SERVICES E+817 (301) 261-4943 ER25-03-0262
PLUMBER BLUESTREAM SERVICES INC PN#220 (410)363-0072 P-0478-25
DEscRlPTloN oF woRK: CONSTRUCT 1 STORY SFD. FIRST FLOOR 35' X 80'4" OVERALL TO INCLUDE 20'6'X 19'8" GARAGE, 1O'2'X 18'8" SCREENED PATIO. AND 5'X 4'4',6'X 16'6" "1" SHAPED FRONT PORCH.
JENKINS DD, PHASE IV
55+ AGE RESTRICTED COMMUNITY
BUII.DiNG DESCRIPTION DIiiIENSIONS (IN SQUARE FEET) CONSTRUCTION TYPE: WOOD FRAME
BASEMENT:
UNFIN. FIN BASEMENT: # EEDROOMS: 2 # BATHROOMS: 2
1.993
FIRST FLOOR: SECOND FLOOR ROAO TYPE: PRIVATE SPRINKLER: YES
FLOOR:
THIRD FOURTH FLOOR WATER TYPE PUBLIC SEWER TYPE PUBLIC
398
GARAGE: CARPORT: HEATING SYSTEM: GAS CENTRAL AIR: YES
DECK:
PORCH:120 FIREPLACE: GAS
oTHER: 190 - SCREENEO PATIO
TOTAL FLOOR AREA: 2.701
The undersigned hereby cerlilles and agrees as tollows: (1 ) That he/she is authorized lo make this applacation; (2) that the information is correct;
(3) that he/she will comply wilh all regulations of Queen Arne's Counly which are applicable theretoi (4) lhal he/she will perform no work on the
above .eferenced property not specifically described in lhis applicationi (5) lhat he/she grants County Offcials the right to enter onto this property for the purpose of inspecting the work permitted and posting nolices.
NOTE: Separate eloctllcal and plumblng pormltg aro rgquiredl A pgimlt under whlch no wo* has commencod wlthin six month3 aft6r bsuanca shall sxplre. A permlt underwhlch work commences withln six months shall bo considgrod lf constructlon ls contlnuous.
Conditions:
OUEEN ANNE'S COUNTY FIRE MARSHALT THIS PERMIT lS APPROVED SUBJECT TO THE ENCLOSED STATED COMI\rENTS. NO INSPECTION WILL BE COMPLETED UNLESS APPROVED STAMPED PLANS AND COMMENTS ARE ON SITE. FOR INFORMATION OR TO ARRANGE AN INSPECTION CALL 4,!O-758-4500 EXT. 1144, LOCATION SURVEY REQUIRED AT TIME OF THE FOUNDATION INSPECTION. OSHA AND MOSHA REGULATIONS REQI,'IRE THAT EACH JOBSITE HAVE TOILET FACILITIES PROVIDED SWM . MUST
FOLLOWAPPROVED SUBDIVISION STORMWATER MANAGEMENT PLAN
OFFICE USE ONLY
MINIMUM YARD REQUIREMENTS APPROVALS:
ACCESSORY STRUCTURE PRINCIPLE STRUCTURE BUTLDTNG +tD ut08t202s Fr ooDPLA[.1 ZONrh]/oe/2025 FRONT FT FROT|T 2A Fr ZONINGMQ 04r30t2025 PLUMBI./G(l/l o4io9/2025 SIDE FT SIDE 5 FT sEDTMENT{v: 01n5t2024 pss 5EWEfPL oa,oyzozs REA S R T REET FT REA S R T REET 1 0 FT HISTORiC s w. l\rGT.vl\J a4rcst2o25
SIDE FT SIDE FT
MAX. HGHT FT MAX. HGHT 40 FT SHA ch :['ffH,D^.S6 ff#:::
MECHANICAL o4lost2025 ELECTRICAL ut08t2025 sAcKFLOw Lul o4tost2o25 HEALr\EN FOOO SERVICE N/A ENV o4ios/1025
ENV. HEALTH WELL
5'?:Oq lllr{n